NORDTEK DANMARK - UI39 - Low Profile Encapsulated PCB Mount Transformer - 10-30VA - transformer.dk

Tell a friend Enquiry print

UI39 - Low Profile Encapsulated PCB Mount Transformer - 10-30VA

A high-quality series of Low Profile safety transformers.

The Low Profile series is ideal for applications with component height restrictions such as where a close spacing between boards is needed.

Typical design is with 2x115V primary for 115V or 230V input at 50/60Hz and dual secondary with two identical output voltages.


Print Layout - UI39 Transformer Pin and Transformer Height UI39 Low Profile safety transformer
     
View from PCB Solder pins 0.8 mm Ø   - Grid 5 mm



 Type
 UI39-0./.../...
 One chamber bobbin
* Stack
Height
mm
Case
height
(H) mm
Weight
g
 Type
 UI39-1./.../...
 Two chamber bobbin
 UI39-.1G/7.../... 6...35V - 10.00 VA 2x6...17.5V - 2x 5.00 VA
70°C/B X nkf 8.0 22.8 295
 UI39-.1F/7.../... 6...35V - 10.00 VA 2x6...17.5V - 2x 5.00 VA
70°C/B X bkf 8.0 22.8 295
 UI39-.2G/7.../... 6...36V - 14.00 VA 2x6...18V - 2x 7.00 VA
70°C/B X nkf 10.2 24.4 330
 UI39-.2F/7.../... 6...36V - 14.00 VA 2x6...18V - 2x 7.00 VA
70°C/B X bkf 10.2 24.4 330
 UI39-.3G/7.../... 6...38V - 18.00 VA 2x6...19V - 2x 9.00 VA
70°C/B X nkf 13.5 27.6 400
 UI39-.3F/7.../... 6...38V - 18.00 VA 2x6...19V - 2x 9.00 VA
70°C/B X bkf 13.5 27.6 400
 UI39-.4G/7.../... 6...40V - 24.00 VA 2x6...20V - 2x12.00 VA
70°C/B X nkf 17.0 31.4 446
 UI39-.4F/7.../... 6...40V - 24.00 VA 2x6...20V - 2x12.00 VA
70°C/B X bkf 17.0 31.4 446
 UI39-.5G/7.../... 6...40V - 30.00 VA 2x6...20V - 2x15.00 VA
70°C/B X nkf 21.0 35.8 563
 UI39-.5G/7.../... 6...40V - 30.00 VA 2x6...20V - 2x15.00 VA
70°C/B X bkf 21.0 35.8 563


  • Approved according EN 61558. VDE 0570
  • Vacuum cast
  • Safety class II
  • Protective system IP 00
  • Conditionally short-circuit proof (*bkf) through built-in temperature fuse,
    or not short-circuit proof (*nkf) but protected by external fuse on primary or secondary



Note: If using the conditionally short-circuit proof transformer type (*bkf) or internally connected (UI39-1./.../...) transformer type, no strip conductors may be guided between the primary connecting pins on the component insertion side, because in this area there is an unprotected live soldering terminal.



Variants available on request


Top of page